ICP-MS
Home - ICP-MS
ICP-MS Method Development & System Proficiency Training
Following our proficient on-site engagement, your staff won't just be certified; They will be advanced operators, fully equipped with the knowledge and confidence that guarantee the continuity of your lab's high-performance operation.

Module 1: ICP-MS Fundamentals and Instrumentation
-
Principles of ICP-MS
-
Review of atomic structure and the ionization process
-
Understanding Mass Spectrometry (MS) principles: mass-to-charge ratio (m/z)
-
-
ICP-MS Instrument Components
-
Detailed function of the Sample Introduction System
-
The Interface and vacuum system
-
Ion Optics and their role in ion focusing
-
Detector types and performance characteristics.
-
-
Basic Operation and Startup
-
Proper instrument startup and shutdown procedures
-
Software familiarization
-
Daily and weekly System Suitability Tests (SST)
-

Module 2: Advanced Method Development & Interference Management
-
Sample Preparation & Matrix Effects
-
Selecting appropriate digestion methods
-
Understanding and mitigating matrix effects
-
The role of internal standards and their correct selection
-
-
Interference Correction Strategies
-
Identifying and correcting Isobaric Interferences
-
Utilizing Collision and Reaction Cells
-
-
Method Optimization & Tuning
-
Optimizing plasma conditions for sensitivity and robustness
-
Tuning procedures, establishing optimum analytical parameters for different sample types
-
-
Calibration and Quantitation
-
Calibration approaches : external calibration, matrix matching, standard addition, isotopic dilution
-
Determining Method Detection Limits (MDL) and Limit of Quantitation (LOQ)
-

Module 3: Validation, Compliance & Data Integrity
-
Method Frameworks
-
Overview of relevant regulations
-
Designing a Validation Protocol checklist specific to ICP-MS parameters (Accuracy, Precision, Linearity, etc.)
-
-
Data Integrity and Auditing
-
Generating audit trails and maintaining records
-
Proper data handling, processing, and reporting protocols.
-
-
Performance Monitoring & OOS
-
Establishing Quality Control (QC) criteria and action limits
-
Procedures for Out-of-Specification (OOS) investigations specific to ICP-MS analysis
-
Change control implementation for method updates.
-

Module 4: System Maintenance and Advanced Troubleshooting
-
Preventative Maintenance
-
Scheduled maintenance for the sample introduction system
-
Cone maintenance: cleaning and replacing sampler/skimmer cones
-
-
Advanced Troubleshooting Logic
-
Systematic diagnosis of common issues: low signal, poor precision, high background noise
-
Identifying the root cause of issues: sample introduction, plasma, or mass spectrometer component failure.
-
-
Minimizing Risk & Operational Success
-
Creating clear, optimized, and documented SOPs for every method
-
Strategies for reducing dependence on a single individual's knowledge.
-
Training syllabus
This course delivers expertise in ICP-MS system proficiency and robust method development. You will gain practical skills to ensure guaranteed compliance and data integrity, alongside advanced maintenance and troubleshooting for sustained, high-quality performance.